Accuracy and reliability of GPS devices for measurement of sports-specific movement patterns related to cricket, tennis, and field-based team sports

William Vickery, Ben Dascombe, John Baker, Dean Higham, Wayne Spratford, Rob Duffield

Research output: Contribution to journalArticle

44 Citations (Scopus)

Abstract

The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ±5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p. 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33%, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = 20.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed. © 2014 National Strength and Conditioning Association.
Original languageEnglish
Pages (from-to)1697-1705
Number of pages9
JournalJournal of Strength and Conditioning Research
Volume28
Issue number6
DOIs
Publication statusPublished - 2014

Fingerprint

Tennis
Gryllidae
Geographic Information Systems
Sports
Equipment and Supplies
Mandrillus
Football
Analysis of Variance

Cite this

@article{4f0a6e28ab04427f8b35a1046279b709,
title = "Accuracy and reliability of GPS devices for measurement of sports-specific movement patterns related to cricket, tennis, and field-based team sports",
abstract = "The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ±5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p. 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33{\%}, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = 20.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed. {\circledC} 2014 National Strength and Conditioning Association.",
author = "William Vickery and Ben Dascombe and John Baker and Dean Higham and Wayne Spratford and Rob Duffield",
year = "2014",
doi = "10.1519/JSC.0000000000000285",
language = "English",
volume = "28",
pages = "1697--1705",
journal = "Journal of Strength and Conditioning Research",
issn = "1064-8011",
publisher = "NSCA National Strength and Conditioning Association",
number = "6",

}

Accuracy and reliability of GPS devices for measurement of sports-specific movement patterns related to cricket, tennis, and field-based team sports. / Vickery, William; Dascombe, Ben; Baker, John; Higham, Dean; Spratford, Wayne; Duffield, Rob.

In: Journal of Strength and Conditioning Research, Vol. 28, No. 6, 2014, p. 1697-1705.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Accuracy and reliability of GPS devices for measurement of sports-specific movement patterns related to cricket, tennis, and field-based team sports

AU - Vickery, William

AU - Dascombe, Ben

AU - Baker, John

AU - Higham, Dean

AU - Spratford, Wayne

AU - Duffield, Rob

PY - 2014

Y1 - 2014

N2 - The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ±5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p. 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33%, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = 20.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed. © 2014 National Strength and Conditioning Association.

AB - The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ±5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p. 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33%, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = 20.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed. © 2014 National Strength and Conditioning Association.

U2 - 10.1519/JSC.0000000000000285

DO - 10.1519/JSC.0000000000000285

M3 - Article

VL - 28

SP - 1697

EP - 1705

JO - Journal of Strength and Conditioning Research

JF - Journal of Strength and Conditioning Research

SN - 1064-8011

IS - 6

ER -