An active orthosis for gait rehabilitation

Shahid Hussain, Sheng Q. Xie

Research output: A Conference proceeding or a Chapter in BookChapter

2 Downloads (Pure)

Abstract

Gait therapy is vital for restoring neuromuscular control in patients suffering from neurological injuries. Robots can provide prolonged, systematic, and repetitive gait training sessions. Currently available robotic devices use stiff actuators with high end point impedance. This work presents a new compliant robotic gait rehabilitation system. Pneumatic muscle actuators (PMAs) were used for actuation purposes. The robotic device is lightweight and works in perfect alignment with patient's joints. The modeling of robotic device with PMA was performed. Model reference-based adaptive control (MRAC) was used to guide the patient's limbs on physiological gait patterns, and joint torques required to achieve these trajectories were measured. The PMA with the proposed design is capable of providing the required joint torques. Simulation studies are reported.

Original languageEnglish
Title of host publicationMechatronics
EditorsJ. Paolo Davim
PublisherJohn Wiley & Sons
Pages169-194
Number of pages26
ISBN (Print)9781848213081
DOIs
Publication statusPublished - 7 Mar 2013
Externally publishedYes

Fingerprint

Patient rehabilitation
Robotics
Actuators
Pneumatics
Muscle
Torque
Trajectories
Robots

Cite this

Hussain, S., & Xie, S. Q. (2013). An active orthosis for gait rehabilitation. In J. P. Davim (Ed.), Mechatronics (pp. 169-194). John Wiley & Sons. https://doi.org/10.1002/9781118614549.ch6
Hussain, Shahid ; Xie, Sheng Q. / An active orthosis for gait rehabilitation. Mechatronics. editor / J. Paolo Davim. John Wiley & Sons, 2013. pp. 169-194
@inbook{6a547ca9d7bd480d88355231f421d4e7,
title = "An active orthosis for gait rehabilitation",
abstract = "Gait therapy is vital for restoring neuromuscular control in patients suffering from neurological injuries. Robots can provide prolonged, systematic, and repetitive gait training sessions. Currently available robotic devices use stiff actuators with high end point impedance. This work presents a new compliant robotic gait rehabilitation system. Pneumatic muscle actuators (PMAs) were used for actuation purposes. The robotic device is lightweight and works in perfect alignment with patient's joints. The modeling of robotic device with PMA was performed. Model reference-based adaptive control (MRAC) was used to guide the patient's limbs on physiological gait patterns, and joint torques required to achieve these trajectories were measured. The PMA with the proposed design is capable of providing the required joint torques. Simulation studies are reported.",
keywords = "Active orthosis, Gait biomechanics, Gait rehabilitation, Rehabilitation robotics, Robotic device modeling",
author = "Shahid Hussain and Xie, {Sheng Q.}",
year = "2013",
month = "3",
day = "7",
doi = "10.1002/9781118614549.ch6",
language = "English",
isbn = "9781848213081",
pages = "169--194",
editor = "Davim, {J. Paolo}",
booktitle = "Mechatronics",
publisher = "John Wiley & Sons",
address = "United States",

}

Hussain, S & Xie, SQ 2013, An active orthosis for gait rehabilitation. in JP Davim (ed.), Mechatronics. John Wiley & Sons, pp. 169-194. https://doi.org/10.1002/9781118614549.ch6

An active orthosis for gait rehabilitation. / Hussain, Shahid; Xie, Sheng Q.

Mechatronics. ed. / J. Paolo Davim. John Wiley & Sons, 2013. p. 169-194.

Research output: A Conference proceeding or a Chapter in BookChapter

TY - CHAP

T1 - An active orthosis for gait rehabilitation

AU - Hussain, Shahid

AU - Xie, Sheng Q.

PY - 2013/3/7

Y1 - 2013/3/7

N2 - Gait therapy is vital for restoring neuromuscular control in patients suffering from neurological injuries. Robots can provide prolonged, systematic, and repetitive gait training sessions. Currently available robotic devices use stiff actuators with high end point impedance. This work presents a new compliant robotic gait rehabilitation system. Pneumatic muscle actuators (PMAs) were used for actuation purposes. The robotic device is lightweight and works in perfect alignment with patient's joints. The modeling of robotic device with PMA was performed. Model reference-based adaptive control (MRAC) was used to guide the patient's limbs on physiological gait patterns, and joint torques required to achieve these trajectories were measured. The PMA with the proposed design is capable of providing the required joint torques. Simulation studies are reported.

AB - Gait therapy is vital for restoring neuromuscular control in patients suffering from neurological injuries. Robots can provide prolonged, systematic, and repetitive gait training sessions. Currently available robotic devices use stiff actuators with high end point impedance. This work presents a new compliant robotic gait rehabilitation system. Pneumatic muscle actuators (PMAs) were used for actuation purposes. The robotic device is lightweight and works in perfect alignment with patient's joints. The modeling of robotic device with PMA was performed. Model reference-based adaptive control (MRAC) was used to guide the patient's limbs on physiological gait patterns, and joint torques required to achieve these trajectories were measured. The PMA with the proposed design is capable of providing the required joint torques. Simulation studies are reported.

KW - Active orthosis

KW - Gait biomechanics

KW - Gait rehabilitation

KW - Rehabilitation robotics

KW - Robotic device modeling

UR - http://www.scopus.com/inward/record.url?scp=84886981285&partnerID=8YFLogxK

U2 - 10.1002/9781118614549.ch6

DO - 10.1002/9781118614549.ch6

M3 - Chapter

SN - 9781848213081

SP - 169

EP - 194

BT - Mechatronics

A2 - Davim, J. Paolo

PB - John Wiley & Sons

ER -

Hussain S, Xie SQ. An active orthosis for gait rehabilitation. In Davim JP, editor, Mechatronics. John Wiley & Sons. 2013. p. 169-194 https://doi.org/10.1002/9781118614549.ch6