Skip to main navigation Skip to search Skip to main content

Assessing the Reliability and Validity of a Balance Mat for Measuring Postural Stability: A Combined Robot-Human Approach

Research output: A Conference proceeding or a Chapter in BookConference contributionpeer-review

Abstract

Postural sway assessment is important for detecting balance problems and identifying people at risk of falls. Force plates (FP) are considered the gold standard postural sway assessment method in laboratory conditions, but their lack of portability and requirement of high-level expertise limit their widespread usage. This study evaluates the reliability and validity of a novel Balance Mat (BM) device, a low-cost portable alternative that uses optical fibre technology. The research includes two studies: a robot study and a human study. In the robot study, a UR10 robotic arm was used to obtain controlled sway patterns to assess the reliability and sensitivity of the BM. In the human study, 51 healthy young participants performed balance tasks on the BM in combination with an FP to evaluate the BM's validity. Sway metrics such as sway mean, sway absolute mean, sway root mean square (RMS), sway path, sway range, and sway velocity were calculated from both BM and FP and compared. Reliability was evaluated using the intra-class correlation coefficient (ICC), where values greater than 0.9 were considered excellent and values between 0.75 and 0.9 were considered good. Results from the robot study demonstrated good to excellent ICC values in both single and double-leg stances. The human study showed moderate to strong correlations for sway path and range. Using Bland-Altman plots for agreement analysis revealed proportional bias between the BM and the FP where the BM overestimated sway metrics compared to the FP. Calibration was used to improve the agreement between the devices. The device demonstrated consistent sway measurement across varied stance conditions, establishing both reliability and validity following appropriate calibration.

Original languageEnglish
Title of host publication20th Edition of the IEEE International Symposium on Medical Measurements and Applications, MeMeA 2025 - Proceedings
EditorsMarco Pavis, Voicu Groza, Petros Spachos, Hilmi Dajani, Marios Antonakakis
PublisherIEEE, Institute of Electrical and Electronics Engineers
Pages1-6
Number of pages6
Edition2025
ISBN (Electronic)9798331523473
DOIs
Publication statusPublished - 2025
Event20th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2025 - Chania, Greece
Duration: 28 May 202530 May 2025

Conference

Conference20th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2025
Country/TerritoryGreece
CityChania
Period28/05/2530/05/25

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Assessing the Reliability and Validity of a Balance Mat for Measuring Postural Stability: A Combined Robot-Human Approach'. Together they form a unique fingerprint.

Cite this