TY - JOUR
T1 - Comparison of Deep Learning-Based and Patch-Based Methods for Pseudo-CT Generation in MRI-Based Prostate Dose Planning
AU - Largent, Axel
AU - Barateau, Anaïs
AU - Nunes, Jean Claude
AU - Mylona, Eugenia
AU - Castelli, Joël
AU - Lafond, Caroline
AU - Greer, Peter B.
AU - Dowling, Jason A.
AU - Baxter, John
AU - Saint-Jalmes, Hervé
AU - Acosta, Oscar
AU - de Crevoisier, Renaud
N1 - Funding Information:
This work was supported by Cancer Council New South Wales research grant rg11-05, the Prostate Cancer Foundation of Australia (Movember Young Investigator grant yi2011), and Cure Cancer Australia.
Publisher Copyright:
© 2019
PY - 2019/12/1
Y1 - 2019/12/1
N2 - Purpose: Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) for magnetic resonance imaging (MRI) based dose planning. This study aims to evaluate and compare DLMs (U-Net and generative adversarial network [GAN]) using various loss functions (L2, single-scale perceptual loss [PL], multiscale PL, weighted multiscale PL) and a patch-based method (PBM). Methods and Materials: Thirty-nine patients received a volumetric modulated arc therapy for prostate cancer (78 Gy). T2-weighted MRIs were acquired in addition to planning CTs. The pCTs were generated from the MRIs using 7 configurations: 4 GANs (L2, single-scale PL, multiscale PL, weighted multiscale PL), 2 U-Net (L2 and single-scale PL), and the PBM. The imaging endpoints were mean absolute error and mean error, in Hounsfield units, between the reference CT (CTref) and the pCT. Dose uncertainties were quantified as mean absolute differences between the dose volume histograms (DVHs) calculated from the CTref and pCT obtained by each method. Three-dimensional gamma indexes were analyzed. Results: Considering the image uncertainties in the whole pelvis, GAN L2 and U-Net L2 showed the lowest mean absolute error (≤34.4 Hounsfield units). The mean errors were not different than 0 (P ≤.05). The PBM provided the highest uncertainties. Very few DVH points differed when comparing GAN L2 or U-Net L2 DVHs and CTref DVHs (P ≤.05). Their dose uncertainties were ≤0.6% for the prostate planning target Volume V95%, ≤0.5% for the rectum V70Gy, and ≤0.1% for the bladder V50Gy. The PBM, U-Net PL, and GAN PL presented the highest systematic dose uncertainties. The gamma pass rates were >99% for all DLMs. The mean calculation time to generate 1 pCT was 15 s for the DLMs and 62 min for the PBM. Conclusions: Generating pCT for MRI dose planning with DLMs and PBM provided low-dose uncertainties. In particular, the GAN L2 and U-Net L2 provided the lowest dose uncertainties together with a low computation time.
AB - Purpose: Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) for magnetic resonance imaging (MRI) based dose planning. This study aims to evaluate and compare DLMs (U-Net and generative adversarial network [GAN]) using various loss functions (L2, single-scale perceptual loss [PL], multiscale PL, weighted multiscale PL) and a patch-based method (PBM). Methods and Materials: Thirty-nine patients received a volumetric modulated arc therapy for prostate cancer (78 Gy). T2-weighted MRIs were acquired in addition to planning CTs. The pCTs were generated from the MRIs using 7 configurations: 4 GANs (L2, single-scale PL, multiscale PL, weighted multiscale PL), 2 U-Net (L2 and single-scale PL), and the PBM. The imaging endpoints were mean absolute error and mean error, in Hounsfield units, between the reference CT (CTref) and the pCT. Dose uncertainties were quantified as mean absolute differences between the dose volume histograms (DVHs) calculated from the CTref and pCT obtained by each method. Three-dimensional gamma indexes were analyzed. Results: Considering the image uncertainties in the whole pelvis, GAN L2 and U-Net L2 showed the lowest mean absolute error (≤34.4 Hounsfield units). The mean errors were not different than 0 (P ≤.05). The PBM provided the highest uncertainties. Very few DVH points differed when comparing GAN L2 or U-Net L2 DVHs and CTref DVHs (P ≤.05). Their dose uncertainties were ≤0.6% for the prostate planning target Volume V95%, ≤0.5% for the rectum V70Gy, and ≤0.1% for the bladder V50Gy. The PBM, U-Net PL, and GAN PL presented the highest systematic dose uncertainties. The gamma pass rates were >99% for all DLMs. The mean calculation time to generate 1 pCT was 15 s for the DLMs and 62 min for the PBM. Conclusions: Generating pCT for MRI dose planning with DLMs and PBM provided low-dose uncertainties. In particular, the GAN L2 and U-Net L2 provided the lowest dose uncertainties together with a low computation time.
UR - http://www.scopus.com/inward/record.url?scp=85074490275&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2019.08.049
DO - 10.1016/j.ijrobp.2019.08.049
M3 - Article
C2 - 31505245
AN - SCOPUS:85074490275
SN - 0360-3016
VL - 105
SP - 1137
EP - 1150
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 5
ER -