T1 - Contact lens-related adverse events and the silicone hydrogel lenses and daily wear care system used
AU - Carnt, Nicole A.
AU - Evans, Victoria E.
AU - Naduvilath, Thomas J.
AU - Willcox, Mark D.P.
AU - Papas, Eric B.
AU - Frick, Kevin D.
AU - Holden, Brien A.
PY - 2009/12
Y1 - 2009/12
N2 - Objective: To investigate the incidence of adverse events related to the use of varying silicone hydrogel contact lens and lens solution combinations. Methods: Individuals with myopia (N=558) participated in 1 or more of approximately 40-participant trials in a matrix of 20 silicone hydrogel contact lens and lenssolution combinations. Visits were at baseline, 2 weeks, 1 month, and 3 months. The mean study completion rate was 90% of the expected participant-months (final data set: 840 lens-solution combinations and 2271 participantmonths). Adverse events were reported as the first occurrence of each type per 100 participant-months for each lens-solution combination. Results: The rate of all corneal infiltrative events (CIEs) was 3.1 per 100 participant-months (range, 0-10.5), and the rate of symptomatic CIEs was 1.7 per 100 participantmonths (range, 0-10.5), including 1 case of microbial keratitis (0.04 per 100 participant-months). Rates for CIEs differed substantially among solution groups, with hydrogen peroxide having the lowest rate (0.6 per 100 participant-months; range, 0-0.9). The rate was 0.8 per 100 participant-months (range, 0-8.0) for superior epithelial arcuate lesions, which varied by lens type, 0.04 per 100 participant-months (1 case only) for corneal erosion, and 0.4 per 100 participant-months (range, 0-2.0) for contact lens papillary conjunctivitis, which was modified by type of solution. The rate of solution-induced corneal staining for all lens-solution combinations was 4.7 per 100 participant-months (range, 0-23) and varied significantly based on lens-solution combination (P<.001). Conclusions: The frequency of adverse events varied with silicone hydrogel contact lens and lens solution combinations, with hydrogen peroxide having the lowest incidence of CIEs and solution-induced corneal staining, indicating that lens material and design, type of solution, and solution-lens interactions are likely contributing factors in this mode of lens wear.
AB - Objective: To investigate the incidence of adverse events related to the use of varying silicone hydrogel contact lens and lens solution combinations. Methods: Individuals with myopia (N=558) participated in 1 or more of approximately 40-participant trials in a matrix of 20 silicone hydrogel contact lens and lenssolution combinations. Visits were at baseline, 2 weeks, 1 month, and 3 months. The mean study completion rate was 90% of the expected participant-months (final data set: 840 lens-solution combinations and 2271 participantmonths). Adverse events were reported as the first occurrence of each type per 100 participant-months for each lens-solution combination. Results: The rate of all corneal infiltrative events (CIEs) was 3.1 per 100 participant-months (range, 0-10.5), and the rate of symptomatic CIEs was 1.7 per 100 participantmonths (range, 0-10.5), including 1 case of microbial keratitis (0.04 per 100 participant-months). Rates for CIEs differed substantially among solution groups, with hydrogen peroxide having the lowest rate (0.6 per 100 participant-months; range, 0-0.9). The rate was 0.8 per 100 participant-months (range, 0-8.0) for superior epithelial arcuate lesions, which varied by lens type, 0.04 per 100 participant-months (1 case only) for corneal erosion, and 0.4 per 100 participant-months (range, 0-2.0) for contact lens papillary conjunctivitis, which was modified by type of solution. The rate of solution-induced corneal staining for all lens-solution combinations was 4.7 per 100 participant-months (range, 0-23) and varied significantly based on lens-solution combination (P<.001). Conclusions: The frequency of adverse events varied with silicone hydrogel contact lens and lens solution combinations, with hydrogen peroxide having the lowest incidence of CIEs and solution-induced corneal staining, indicating that lens material and design, type of solution, and solution-lens interactions are likely contributing factors in this mode of lens wear.
UR - http://www.scopus.com/inward/record.url?scp=73349099379&partnerID=8YFLogxK
U2 - 10.1001/archophthalmol.2009.313
DO - 10.1001/archophthalmol.2009.313
M3 - Article
C2 - 20008717
AN - SCOPUS:73349099379
SN - 0003-9950
VL - 127
SP - 1616
EP - 1623
JO - Archives of Ophthalmology
JF - Archives of Ophthalmology
IS - 12
ER -