TY - JOUR
T1 - Effects of digital filtering on peak acceleration and force measurements for artistic gymnastics skills
AU - Campbell, Rhiannon A.
AU - Bradshaw, Elizabeth J.
AU - Ball, Nick
AU - Hunter, Adam
AU - Spratford, Wayne
N1 - Publisher Copyright:
© 2020 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2020/8/17
Y1 - 2020/8/17
N2 - Low-pass filters are ideal when filtering human movements, however the effectiveness of such filters relies on the correct selection of the cut-off frequency. The aim of this study was to determine the most appropriate filter cut-off for acceleration- and force-time data when measuring peak resultant acceleration (PRA) and ground reaction force (PRGRF) during gymnastics landings. Sixteen gymnasts executed backward handsprings and backward somersault landings onto a matted force plate while wearing four inertial measurement units (IMUs). Acceleration- and force-time data were filtered using a fourth-order Butterworth filter at different cut-off frequencies ranging from raw through to 250 Hz. Residual analysis plots were produced, and the PRGRF and PRA for all IMUs were calculated for each participant and skill at all cut-off frequencies. Descriptive statistics, model II linear regressions and Bland-Altman plots were conducted. Results indicated that a minimum 85 Hz cut-off is optimal. High cut-off frequencies (>80 Hz) showed good linear relationships and had minimal mean bias compared with raw values, indicating that either filtered (above ~85 Hz) or raw signals can be used. It is suggested that for applied sports settings no filtering is needed, however a minimum cut-off of 85 Hz should be implemented for research purposes.
AB - Low-pass filters are ideal when filtering human movements, however the effectiveness of such filters relies on the correct selection of the cut-off frequency. The aim of this study was to determine the most appropriate filter cut-off for acceleration- and force-time data when measuring peak resultant acceleration (PRA) and ground reaction force (PRGRF) during gymnastics landings. Sixteen gymnasts executed backward handsprings and backward somersault landings onto a matted force plate while wearing four inertial measurement units (IMUs). Acceleration- and force-time data were filtered using a fourth-order Butterworth filter at different cut-off frequencies ranging from raw through to 250 Hz. Residual analysis plots were produced, and the PRGRF and PRA for all IMUs were calculated for each participant and skill at all cut-off frequencies. Descriptive statistics, model II linear regressions and Bland-Altman plots were conducted. Results indicated that a minimum 85 Hz cut-off is optimal. High cut-off frequencies (>80 Hz) showed good linear relationships and had minimal mean bias compared with raw values, indicating that either filtered (above ~85 Hz) or raw signals can be used. It is suggested that for applied sports settings no filtering is needed, however a minimum cut-off of 85 Hz should be implemented for research purposes.
KW - accelerometer
KW - biomechanics
KW - landing
KW - load
KW - Training
UR - http://www.scopus.com/inward/record.url?scp=85085027592&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/2324ff37-4803-3db7-b961-b46b5e5834db/
U2 - 10.1080/02640414.2020.1757374
DO - 10.1080/02640414.2020.1757374
M3 - Article
AN - SCOPUS:85085027592
SN - 0264-0414
VL - 38
SP - 1859
EP - 1868
JO - Journal of Sports Sciences
JF - Journal of Sports Sciences
IS - 16
ER -