Factors affecting contrast-detail performance in computed tomography

A review

Haney Alsleem, Rob DAVIDSON

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

This article reports on recent research findings into the factors that influence the detectability performance of different systems of computed tomography (CT) scanners. These systems include multidetector CT (MDCT) of different slice numbers, dual-source CT (DSCT), and cone-beam CT (CBCT). The introduction of more slices for MDCT, DSCT, and the new technology of CBCT increases the need to optimize the image quality and to examine the potential reduction of radiation doses to the patient. Low-contrast detail detectability is a method that has proven to be an appropriate evaluation method for this purpose. However, it is essential to recognize factors that affect detectability performance and understand how these factors influence image quality and radiation dose. It is argued that deep understanding of the influences of these factors is the key to image quality optimization in terms of contrast-detail detectability and radiation dose reduction. The purpose of this article is, therefore, to specify these factors and to explain their influence on detectability performance and hence on CT image quality. Further low-contrast detail studies are required to optimize imaging performance of different CT systems and scanners.

Original languageEnglish
Pages (from-to)62-70
Number of pages9
JournalJournal of Medical Imaging and Radiation Sciences
Volume44
Issue number2
DOIs
Publication statusPublished - 2013
Externally publishedYes

Fingerprint

Cone-Beam Computed Tomography
X-Ray Computed Tomography Scanners
Tomography
Radiation
Multidetector Computed Tomography
Technology
Research

Cite this

@article{47299ec0de0b45fdb0734e555e45822c,
title = "Factors affecting contrast-detail performance in computed tomography: A review",
abstract = "This article reports on recent research findings into the factors that influence the detectability performance of different systems of computed tomography (CT) scanners. These systems include multidetector CT (MDCT) of different slice numbers, dual-source CT (DSCT), and cone-beam CT (CBCT). The introduction of more slices for MDCT, DSCT, and the new technology of CBCT increases the need to optimize the image quality and to examine the potential reduction of radiation doses to the patient. Low-contrast detail detectability is a method that has proven to be an appropriate evaluation method for this purpose. However, it is essential to recognize factors that affect detectability performance and understand how these factors influence image quality and radiation dose. It is argued that deep understanding of the influences of these factors is the key to image quality optimization in terms of contrast-detail detectability and radiation dose reduction. The purpose of this article is, therefore, to specify these factors and to explain their influence on detectability performance and hence on CT image quality. Further low-contrast detail studies are required to optimize imaging performance of different CT systems and scanners.",
author = "Haney Alsleem and Rob DAVIDSON",
year = "2013",
doi = "10.1016/j.jmir.2012.12.001",
language = "English",
volume = "44",
pages = "62--70",
journal = "The Canadian journal of medical radiation technology / CAMRT",
issn = "0820-5930",
publisher = "Elsevier Inc.",
number = "2",

}

Factors affecting contrast-detail performance in computed tomography : A review. / Alsleem, Haney; DAVIDSON, Rob.

In: Journal of Medical Imaging and Radiation Sciences, Vol. 44, No. 2, 2013, p. 62-70.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Factors affecting contrast-detail performance in computed tomography

T2 - A review

AU - Alsleem, Haney

AU - DAVIDSON, Rob

PY - 2013

Y1 - 2013

N2 - This article reports on recent research findings into the factors that influence the detectability performance of different systems of computed tomography (CT) scanners. These systems include multidetector CT (MDCT) of different slice numbers, dual-source CT (DSCT), and cone-beam CT (CBCT). The introduction of more slices for MDCT, DSCT, and the new technology of CBCT increases the need to optimize the image quality and to examine the potential reduction of radiation doses to the patient. Low-contrast detail detectability is a method that has proven to be an appropriate evaluation method for this purpose. However, it is essential to recognize factors that affect detectability performance and understand how these factors influence image quality and radiation dose. It is argued that deep understanding of the influences of these factors is the key to image quality optimization in terms of contrast-detail detectability and radiation dose reduction. The purpose of this article is, therefore, to specify these factors and to explain their influence on detectability performance and hence on CT image quality. Further low-contrast detail studies are required to optimize imaging performance of different CT systems and scanners.

AB - This article reports on recent research findings into the factors that influence the detectability performance of different systems of computed tomography (CT) scanners. These systems include multidetector CT (MDCT) of different slice numbers, dual-source CT (DSCT), and cone-beam CT (CBCT). The introduction of more slices for MDCT, DSCT, and the new technology of CBCT increases the need to optimize the image quality and to examine the potential reduction of radiation doses to the patient. Low-contrast detail detectability is a method that has proven to be an appropriate evaluation method for this purpose. However, it is essential to recognize factors that affect detectability performance and understand how these factors influence image quality and radiation dose. It is argued that deep understanding of the influences of these factors is the key to image quality optimization in terms of contrast-detail detectability and radiation dose reduction. The purpose of this article is, therefore, to specify these factors and to explain their influence on detectability performance and hence on CT image quality. Further low-contrast detail studies are required to optimize imaging performance of different CT systems and scanners.

U2 - 10.1016/j.jmir.2012.12.001

DO - 10.1016/j.jmir.2012.12.001

M3 - Article

VL - 44

SP - 62

EP - 70

JO - The Canadian journal of medical radiation technology / CAMRT

JF - The Canadian journal of medical radiation technology / CAMRT

SN - 0820-5930

IS - 2

ER -