TY - JOUR
T1 - Investigating the application of motion accelerometers as a sleep monitoring technique and the clinical burden of the intensive care environment on sleep quality: Study protocol for a prospective observational study in Australia.
AU - DELANEY, Lori
AU - CURRIE, Marian
AU - Huang, Hsin-Chia Carol
AU - Litton, Edward
AU - Wilbrow, Bradley
AU - Lopez, Violeta
AU - Van Haren, Frank
PY - 2018/1/1
Y1 - 2018/1/1
N2 - Introduction Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals' physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. Key measures The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. Methods and analysis A prospective, single centre observational design with a within subjects' assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and '(moderate sedation) and an anticipated length of stay >24 hours. Patients' sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients' self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients' perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. Ethics and dissemination The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. Trial registration number ACTRN12615000945527; Pre-results.
AB - Introduction Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals' physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. Key measures The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. Methods and analysis A prospective, single centre observational design with a within subjects' assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and '(moderate sedation) and an anticipated length of stay >24 hours. Patients' sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients' self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients' perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. Ethics and dissemination The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. Trial registration number ACTRN12615000945527; Pre-results.
KW - actigraphy
KW - clinical environment
KW - intensive care
KW - polysomnography
KW - sleep medicine
KW - Severity of Illness Index
KW - Accelerometry/methods
KW - Prospective Studies
KW - Humans
KW - Self Report
KW - Critical Illness
KW - Sleep Wake Disorders/diagnosis
KW - Monitoring, Physiologic/methods
KW - Polysomnography
KW - Sleep
KW - Intensive Care Units/organization & administration
KW - Australia
KW - Research Design
UR - http://www.scopus.com/inward/record.url?scp=85051616733&partnerID=8YFLogxK
UR - http://www.mendeley.com/research/investigating-application-motion-accelerometers-sleep-monitoring-technique-clinical-burden-intensive
U2 - 10.1136/bmjopen-2017-019704
DO - 10.1136/bmjopen-2017-019704
M3 - Article
C2 - 29358448
SN - 2044-6055
VL - 8
SP - 1
EP - 9
JO - BMJ Open
JF - BMJ Open
IS - 1
M1 - e019704
ER -