TY - JOUR
T1 - Potential Benefits of Continuous Glucose Monitoring for Predicting Vascular Outcomes in Type 2 Diabetes
T2 - A Rapid Review of Primary Research
AU - Jadav, Radhika Kiritsinh
AU - YEE, Kwang Choon
AU - Turner, Murray R.
AU - MORTAZAVI, Reza
N1 - Publisher Copyright:
© 2024 by the authors.
PY - 2024/8/4
Y1 - 2024/8/4
N2 - Background: Chronic hyperglycaemia is a cause of vascular damage and other adverse clinical outcomes in type 2 diabetes mellitus (T2DM). Emerging evidence suggests a significant and independent role for glycaemic variability (GV) in contributing to those outcomes. Continuous glucose monitoring (CGM) provides valuable insights into GV. Unlike in type 1 diabetes mellitus, the use of CGM-derived GV indices has not been widely adopted in the management of T2DM due to the limited evidence of their effectiveness in predicting clinical outcomes. This study aimed to explore the associations between GV metrics and short- or long-term vascular and clinical complications in T2DM. Methods: A rapid literature review was conducted using the Cochrane Library, MEDLINE, and Scopus databases to seek high-level evidence. Lower-quality studies such as cross-sectional studies were excluded, but their content was reviewed.Results: Six studies (five prospective cohort studies and one clinical trial) reported associations between GV indices (coefficient of variation (CV), standard deviation (SD), Mean Amplitude of Glycaemic Excursions (MAGE), Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR)), and clinical complications. However, since most evidence came from moderate to low-quality studies, the results should be interpreted with caution. (4) Conclusions: Limited but significant evidence suggests that GV indices may predict clinical compilations in T2DM both in the short term and long term. There is a need for longitudinal studies in larger and more diverse populations, longer follow-ups, and the use of numerous CGM-derived GV indices while collecting information about all microvascular and macrovascular complications.
AB - Background: Chronic hyperglycaemia is a cause of vascular damage and other adverse clinical outcomes in type 2 diabetes mellitus (T2DM). Emerging evidence suggests a significant and independent role for glycaemic variability (GV) in contributing to those outcomes. Continuous glucose monitoring (CGM) provides valuable insights into GV. Unlike in type 1 diabetes mellitus, the use of CGM-derived GV indices has not been widely adopted in the management of T2DM due to the limited evidence of their effectiveness in predicting clinical outcomes. This study aimed to explore the associations between GV metrics and short- or long-term vascular and clinical complications in T2DM. Methods: A rapid literature review was conducted using the Cochrane Library, MEDLINE, and Scopus databases to seek high-level evidence. Lower-quality studies such as cross-sectional studies were excluded, but their content was reviewed.Results: Six studies (five prospective cohort studies and one clinical trial) reported associations between GV indices (coefficient of variation (CV), standard deviation (SD), Mean Amplitude of Glycaemic Excursions (MAGE), Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR)), and clinical complications. However, since most evidence came from moderate to low-quality studies, the results should be interpreted with caution. (4) Conclusions: Limited but significant evidence suggests that GV indices may predict clinical compilations in T2DM both in the short term and long term. There is a need for longitudinal studies in larger and more diverse populations, longer follow-ups, and the use of numerous CGM-derived GV indices while collecting information about all microvascular and macrovascular complications.
KW - diabetes mellitus
KW - T2DM
KW - glycaemic variability
KW - vascular complications
KW - glucose fluctuations
KW - glucose excursions
KW - continuous glucose monitoring
KW - CGM
KW - rtCGM
KW - isCGM
UR - http://www.scopus.com/inward/record.url?scp=85200851242&partnerID=8YFLogxK
U2 - 10.3390/healthcare12151542
DO - 10.3390/healthcare12151542
M3 - Review article
AN - SCOPUS:85200851242
SN - 2227-9032
VL - 12
SP - 1542
EP - 1558
JO - Healthcare (Switzerland)
JF - Healthcare (Switzerland)
IS - 15
ER -