Reproducibility of pacing strategy during simulated 20-km cycling time trials in well-trained cyclists

Kevin Thomas, Mark Stone, Kevin Thompson, Alan St Claire Gibson, Les Ansley

    Research output: Contribution to journalArticle

    39 Citations (Scopus)

    Abstract

    The aim of the study was to assess the reproducibility of pacing strategy, physiological and perceptual responses during simulated 20-km cycling time trials. Seventeen well-trained male cyclists ([Formula: see text] = 4.70 ± 0.33 L min(-1)) completed three 20-km time trials on a Velotron Pro cycle ergometer within a maximum duration of 14 days. During all trials power output, cadence and respiratory exchange were recorded throughout, rating of perceived exertion and affective response were recorded every 2-km and capillary blood was sampled and assayed for the determination of lactate concentration every 4-km. Power output data was assigned to 1-km 'bins' and expressed relative to the mean to quantify pacing strategy. Reproducibility of the pacing strategy and the whole trial mean responses was subsequently quantified using typical error (TE) with 90% confidence intervals. The pacing strategy adopted was similar across repeat trials, though there was a higher degree of variability at the start and end of the trial (TE = 6.6 and 6.8% for the first and last 1-km), and a trend for a progressively blunted start on repeat trials. The reproducibility of performance, cardiorespiratory and perceptual measures was good (TE range 1.0-4.0%), but blood lactate exhibited higher variability (TE = 17.7%). The results demonstrate the performance, perceptual and physiological response to self-paced 20-km time trials is reproducible in well-trained cyclists. Future research should acknowledge that variability in pacing strategy at the start and end of a self-paced bout is likely regardless of any intervention employed.

    Original languageEnglish
    Pages (from-to)223-229
    Number of pages7
    JournalEuropean Journal of Applied Physiology
    Volume112
    Issue number1
    DOIs
    Publication statusPublished - 2012

    Fingerprint

    Lactic Acid
    Confidence Intervals

    Cite this

    Thomas, Kevin ; Stone, Mark ; Thompson, Kevin ; St Claire Gibson, Alan ; Ansley, Les. / Reproducibility of pacing strategy during simulated 20-km cycling time trials in well-trained cyclists. In: European Journal of Applied Physiology. 2012 ; Vol. 112, No. 1. pp. 223-229.
    @article{7dff849db1a54b09b8f1d76bf91a916b,
    title = "Reproducibility of pacing strategy during simulated 20-km cycling time trials in well-trained cyclists",
    abstract = "The aim of the study was to assess the reproducibility of pacing strategy, physiological and perceptual responses during simulated 20-km cycling time trials. Seventeen well-trained male cyclists ([Formula: see text] = 4.70 ± 0.33 L min(-1)) completed three 20-km time trials on a Velotron Pro cycle ergometer within a maximum duration of 14 days. During all trials power output, cadence and respiratory exchange were recorded throughout, rating of perceived exertion and affective response were recorded every 2-km and capillary blood was sampled and assayed for the determination of lactate concentration every 4-km. Power output data was assigned to 1-km 'bins' and expressed relative to the mean to quantify pacing strategy. Reproducibility of the pacing strategy and the whole trial mean responses was subsequently quantified using typical error (TE) with 90{\%} confidence intervals. The pacing strategy adopted was similar across repeat trials, though there was a higher degree of variability at the start and end of the trial (TE = 6.6 and 6.8{\%} for the first and last 1-km), and a trend for a progressively blunted start on repeat trials. The reproducibility of performance, cardiorespiratory and perceptual measures was good (TE range 1.0-4.0{\%}), but blood lactate exhibited higher variability (TE = 17.7{\%}). The results demonstrate the performance, perceptual and physiological response to self-paced 20-km time trials is reproducible in well-trained cyclists. Future research should acknowledge that variability in pacing strategy at the start and end of a self-paced bout is likely regardless of any intervention employed.",
    keywords = "Cardiorespiratory, Cycling, Pacing strategy, Reliability, Reproducibility, Time-trial",
    author = "Kevin Thomas and Mark Stone and Kevin Thompson and {St Claire Gibson}, Alan and Les Ansley",
    year = "2012",
    doi = "10.1007/s00421-011-1974-4",
    language = "English",
    volume = "112",
    pages = "223--229",
    journal = "European Journal of Applied Physiology and Occupational Physiology",
    issn = "1439-6319",
    publisher = "Springer Verlag",
    number = "1",

    }

    Reproducibility of pacing strategy during simulated 20-km cycling time trials in well-trained cyclists. / Thomas, Kevin; Stone, Mark; Thompson, Kevin; St Claire Gibson, Alan; Ansley, Les.

    In: European Journal of Applied Physiology, Vol. 112, No. 1, 2012, p. 223-229.

    Research output: Contribution to journalArticle

    TY - JOUR

    T1 - Reproducibility of pacing strategy during simulated 20-km cycling time trials in well-trained cyclists

    AU - Thomas, Kevin

    AU - Stone, Mark

    AU - Thompson, Kevin

    AU - St Claire Gibson, Alan

    AU - Ansley, Les

    PY - 2012

    Y1 - 2012

    N2 - The aim of the study was to assess the reproducibility of pacing strategy, physiological and perceptual responses during simulated 20-km cycling time trials. Seventeen well-trained male cyclists ([Formula: see text] = 4.70 ± 0.33 L min(-1)) completed three 20-km time trials on a Velotron Pro cycle ergometer within a maximum duration of 14 days. During all trials power output, cadence and respiratory exchange were recorded throughout, rating of perceived exertion and affective response were recorded every 2-km and capillary blood was sampled and assayed for the determination of lactate concentration every 4-km. Power output data was assigned to 1-km 'bins' and expressed relative to the mean to quantify pacing strategy. Reproducibility of the pacing strategy and the whole trial mean responses was subsequently quantified using typical error (TE) with 90% confidence intervals. The pacing strategy adopted was similar across repeat trials, though there was a higher degree of variability at the start and end of the trial (TE = 6.6 and 6.8% for the first and last 1-km), and a trend for a progressively blunted start on repeat trials. The reproducibility of performance, cardiorespiratory and perceptual measures was good (TE range 1.0-4.0%), but blood lactate exhibited higher variability (TE = 17.7%). The results demonstrate the performance, perceptual and physiological response to self-paced 20-km time trials is reproducible in well-trained cyclists. Future research should acknowledge that variability in pacing strategy at the start and end of a self-paced bout is likely regardless of any intervention employed.

    AB - The aim of the study was to assess the reproducibility of pacing strategy, physiological and perceptual responses during simulated 20-km cycling time trials. Seventeen well-trained male cyclists ([Formula: see text] = 4.70 ± 0.33 L min(-1)) completed three 20-km time trials on a Velotron Pro cycle ergometer within a maximum duration of 14 days. During all trials power output, cadence and respiratory exchange were recorded throughout, rating of perceived exertion and affective response were recorded every 2-km and capillary blood was sampled and assayed for the determination of lactate concentration every 4-km. Power output data was assigned to 1-km 'bins' and expressed relative to the mean to quantify pacing strategy. Reproducibility of the pacing strategy and the whole trial mean responses was subsequently quantified using typical error (TE) with 90% confidence intervals. The pacing strategy adopted was similar across repeat trials, though there was a higher degree of variability at the start and end of the trial (TE = 6.6 and 6.8% for the first and last 1-km), and a trend for a progressively blunted start on repeat trials. The reproducibility of performance, cardiorespiratory and perceptual measures was good (TE range 1.0-4.0%), but blood lactate exhibited higher variability (TE = 17.7%). The results demonstrate the performance, perceptual and physiological response to self-paced 20-km time trials is reproducible in well-trained cyclists. Future research should acknowledge that variability in pacing strategy at the start and end of a self-paced bout is likely regardless of any intervention employed.

    KW - Cardiorespiratory

    KW - Cycling

    KW - Pacing strategy

    KW - Reliability

    KW - Reproducibility

    KW - Time-trial

    U2 - 10.1007/s00421-011-1974-4

    DO - 10.1007/s00421-011-1974-4

    M3 - Article

    VL - 112

    SP - 223

    EP - 229

    JO - European Journal of Applied Physiology and Occupational Physiology

    JF - European Journal of Applied Physiology and Occupational Physiology

    SN - 1439-6319

    IS - 1

    ER -