TY - JOUR
T1 - The Diagnostic Accuracy of Noninvasive Methods to Measure the Intracranial Pressure
T2 - A Systematic Review and Meta-analysis
AU - Sallam, Amr
AU - Alkhatip, Ahmed Mahmoud M.
AU - Kamel, Mohamed Gomaa
AU - Hamza, Mohamed Khaled
AU - Yassin, Hany Mahmoud
AU - Hosny, Hisham
AU - Younis, Mohamed I.
AU - Ramadan, Eslam
AU - Algameel, Haytham Zien
AU - Abdelhaq, Mohamed
AU - Abdelkader, Mohamed
AU - Mills, Kerry E.
AU - Mohamed, Hassan
N1 - Publisher Copyright:
© 2021 Lippincott Williams and Wilkins. All rights reserved.
PY - 2021/3/1
Y1 - 2021/3/1
N2 - BACKGROUND: Although invasive monitoring is the standard method for intracranial pressure (ICP) measurement, it is not without potential for serious complications. Noninvasive methods have been proposed as alternatives to invasive ICP monitoring. The study aimed to investigate the diagnostic accuracy of the currently available noninvasive methods for intracranial hypertension (ICH) monitoring. METHODS: We searched 5 databases for articles evaluating the diagnostic accuracy of noninvasive methods in diagnosing ICH in PubMed, Institute of Science Index, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), and Embase. The quantitative analysis was conducted if there were at least 2 studies evaluating a specific method. The accuracy measures included the sensitivity, specificity, likelihood ratios, and diagnostic odds ratio. RESULTS: We included 134 articles. Ultrasonographic optic nerve sheath diameter (US ONSD) had high diagnostic accuracy (estimated sensitivity of 90%; 95% confidence interval [CI], 87-92, estimated specificity of 88%; 95% CI, 84-91) while the magnetic resonance imaging (MRI) ONSD had estimated sensitivity of 77%; 95% CI, 64-87 and estimated specificity of 89%; 95% CI, 84-93, and computed tomography (CT) ONSD had estimated sensitivity of 93%; 95% CI, 90-96 and estimated specificity of 79%; 95% CI, 56-92. All MRI signs had a very high estimated specificity ranging from 90% to 99% but a low estimated sensitivity except for sinus stenosis which had high estimated sensitivity as well as specificity (90%; 95% CI, 75-96 and 96%; 95% CI, 91-99, respectively). Among the physical examination signs, pupillary dilation had a high estimated specificity (86%; 95% CI, 76-93). Other diagnostic tests to be considered included pulsatility index, papilledema, transcranial Doppler, compression or absence of basal cisterns, and ≥10 mm midline shift. Setting the cutoff value of ICH to ≥20 mm Hg instead of values <20 mm Hg was associated with higher sensitivity. Moreover, if the delay between invasive and noninvasive methods was within 1 hour, the MRI ONSD and papilledema had a significantly higher diagnostic accuracy compared to the >1 hour subgroup. CONCLUSIONS: Our study showed several promising tools for diagnosing ICH. Moreover, we demonstrated that using multiple, readily available, noninvasive methods is better than depending on a single sign such as physical examination or CT alone.
AB - BACKGROUND: Although invasive monitoring is the standard method for intracranial pressure (ICP) measurement, it is not without potential for serious complications. Noninvasive methods have been proposed as alternatives to invasive ICP monitoring. The study aimed to investigate the diagnostic accuracy of the currently available noninvasive methods for intracranial hypertension (ICH) monitoring. METHODS: We searched 5 databases for articles evaluating the diagnostic accuracy of noninvasive methods in diagnosing ICH in PubMed, Institute of Science Index, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), and Embase. The quantitative analysis was conducted if there were at least 2 studies evaluating a specific method. The accuracy measures included the sensitivity, specificity, likelihood ratios, and diagnostic odds ratio. RESULTS: We included 134 articles. Ultrasonographic optic nerve sheath diameter (US ONSD) had high diagnostic accuracy (estimated sensitivity of 90%; 95% confidence interval [CI], 87-92, estimated specificity of 88%; 95% CI, 84-91) while the magnetic resonance imaging (MRI) ONSD had estimated sensitivity of 77%; 95% CI, 64-87 and estimated specificity of 89%; 95% CI, 84-93, and computed tomography (CT) ONSD had estimated sensitivity of 93%; 95% CI, 90-96 and estimated specificity of 79%; 95% CI, 56-92. All MRI signs had a very high estimated specificity ranging from 90% to 99% but a low estimated sensitivity except for sinus stenosis which had high estimated sensitivity as well as specificity (90%; 95% CI, 75-96 and 96%; 95% CI, 91-99, respectively). Among the physical examination signs, pupillary dilation had a high estimated specificity (86%; 95% CI, 76-93). Other diagnostic tests to be considered included pulsatility index, papilledema, transcranial Doppler, compression or absence of basal cisterns, and ≥10 mm midline shift. Setting the cutoff value of ICH to ≥20 mm Hg instead of values <20 mm Hg was associated with higher sensitivity. Moreover, if the delay between invasive and noninvasive methods was within 1 hour, the MRI ONSD and papilledema had a significantly higher diagnostic accuracy compared to the >1 hour subgroup. CONCLUSIONS: Our study showed several promising tools for diagnosing ICH. Moreover, we demonstrated that using multiple, readily available, noninvasive methods is better than depending on a single sign such as physical examination or CT alone.
UR - http://www.scopus.com/inward/record.url?scp=85101372464&partnerID=8YFLogxK
U2 - 10.1213/ANE.0000000000005189
DO - 10.1213/ANE.0000000000005189
M3 - Article
C2 - 32991330
AN - SCOPUS:85101372464
SN - 0003-2999
VL - 132
SP - 686
EP - 695
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
IS - 3
ER -